Research on the Difference in Measuring the Same Liquid Level Height During the Commissioning of Float-type and Differential Pressure-type Liquid Level Gauge Equipment
ZHANG Yifei
SHAO Shiqi
BIAN Na
SUN Xiaodong
SONG Guibin
NIE Maozeng
Abstract:Based on the measurement principles,verification,installation,and usage of float-type and differential pressure-type liquid level gauges,this paper discusses their on-site installation,commissioning,and precautions.Additionally,it conducts research on the height difference issues that arise during on-site water commissioning.
Keywords:float-typedifferential pressure typelevel gaugeverificationdebug
Publication Date:2026-06-30
Online Publishing Date:2026-11-18(First online date of this platform, not the publication date of the document)
Pages:3( 119-121 )
Metrology & Measurement Technique

Metrology & Measurement Technique

ISSN:1004-6941
Year, Vol.(Issue):2026,52(6)