Research on MEMS Gyroscopic Attitude Angle Traceback Technology
WANG Peng
ZHAO Hongliang
WANG Deli
LI Feng
Abstract:To address the calibration issues of MEMS gyroscope attitude angle measurement performance,a method was proposed invol-ving the use of a multi-axis turntable for heading angle calibration and a high-precision turntable for pitch and roll angle calibra-tion.The results indicate that the indicated errors for pitch,roll,and heading angles exhibit linear variation(with the smallest errors near 0°),increasing as the rotation angle grows(maximum values of-2°,-2.01°,and-2.95°,respectively).The repeatability after reset was 0.041°,0.065°,and 0.27°,all exceeding one-third of the corresponding performance indicators,while the R2 values of the indicated error fitting curves approached 1,demonstrating high prediction accuracy.This method can serve as a reference for MEMS gy-roscope metrological traceability.
Keywords:MEMS gyroscopeprecision turntableattitude anglemulti-tooth turntable
Publication Date:2026-03-31
Online Publishing Date:2026-11-18(First online date of this platform, not the publication date of the document)
Pages:5( 8-12 )