Influencing factors of operating temperature of denitration SCR reactor
GU Qinghua
HU Xiuli
Abstract:The lower operating temperature of SCR denitration reactor directly caused catalyst deactivation. In order to resolve this problem, taking the typical SCR denitration system of 600 MW coal-fired unit as research object,the influence of reaction temperature,NH3 HSO4 formation temperature in catalytic reaction region,sprayed ammonia diluted wind and permissible error of temperature measurement compo-nents on the temperature of denitration area was analyzed. The minimum safe operating temperature of SCR denitration reactor was deter-mined. The results showed that,the activation temperature of vanadium-tungsten-titanium catalyst ranged from 320 ℃ to 420 ℃. When the temperature was between 340 ℃ and 380 ℃,the reaction had the best performance and the denitration efficiency reached about 90%. The condensation temperature of NH3 HSO4 which was the major component in gas phase was between 270 ℃and 320 ℃. The sprayed am-monia diluted wind reduced the denitration temperature by 2. 6 ℃ to 2. 9 ℃. The permissible error of temperature measurement compo-nents had relatively fixed influence on SCR denitration reactor,the maximum reduction was about 4 ℃. At last,the inlet temperature was determined in the range of 350 ℃ and 390 ℃.
Keywords:selective catalytic reductionoperating temperaturedenitration SCR reactorNH3 HSO4
Publication Date:2015-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:4( 77-80 )
Clean Coal Technology

Clean Coal Technology

ISTIC
ISSN:1006-6772
Year, Vol.(Issue):2015,(2)