Design research and application of cyclone separator outlet steam-cooled flue
CHEN Zhen-yu
SHI You
WEN Lin-chun
LU Jia-yi
SU Hu
LIU You-li
HU Shi-lei
LYU Zhuo
Abstract:Based on the existing cyclone separator outlet flue,Dongfang Electric Group Dongfang Boiler Co.,Ltd.(hereinafter referred to as'Dongfang Boiler')has independently developed a cyclone separator outlet steam-cooled flue scheme to further enhance the performance of the boiler.Taking a 350 MW supercritical circulating fluidized bed(CFB)boiler unit as the object of design verification,this paper conducts an in-depth analysis of the scheme of the steam-cooled flue,the stress of the steam-cooled flue,and the wear of the steam-cooled flue,and proposes targeted solutions.The independently developed cyclone separator outlet steam-cooled flue has been successfully applied in various grades of multiple CFB boilers,laying the foundation for further achieving clean and efficient utilization of CFB boilers.
Keywords:circulating fluidized bed boilercyclone separatorsteam-cooled flue
Publication Date:2024-07-15
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 107-109 )
Energy Conservation

Energy Conservation

ISSN:1004-7948
Year, Vol.(Issue):2024,43(7)