Application of ground electric field monitoring in prevention of roof water inrush in 7130 wo rki ng face of Qidong coal mine
SUN Chang-li
WANG Jing-ming
Abstract:Roof water source for the "four-containing"is the the largest sources of danger that threat 7130 Face in Qidong Coal Mine ’ s Safety Production.Mining will form the the rupture zones of roof strata , it’ s elec-trical properties will change significant .By monitoring the changes of resistance , excitation current and natural potential, we found that there is a certain corresponding relation between the roof water inrush quantity and goaf water inflow.Through the monitoring tests in Qidong Coal Mine , it shows that the roof water damage is can be predicted ,the amount of advance warning of natural potential is up to 25 days, a minimum of 5 days and the exciting current is up 26 days, a minimum of two days.This prediction method can be referenced to other coal mine to prevent roof water flood threats .
Keywords:Roof water damageHydrogeological effectsElectric effectsWater hazard warning
Publication Date:2016-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:6( 39-44 )