Clinical Application and Evaluation of Levonorgestrel-releasing Intrauterine System
TIAN Ying
LANG Yu-ping
WEI Zhen-he
DONG Yan
YANG Hua
Abstract: Objective: To observe the clinical application of levonorgestrel-releasing intrauterine system (LNG-IUS),and to evaluate the effeciency of resetting the downward shifted LNG-IUS. Methods:Total 152 patients with LNG-IUS were follow-up visited,to assess the degree of dysmenorrheal,the extent of menstrual bleeding and the position of LNG-IUS in uterine. The reposition under the guidance of B ultrasound were performed in 45 cases with ectopic LNG-IUS. Results:Both VAS grade and PBAC grade after inserting the LNG-IUS were significantly lowered when compared with their pre-deposited grades(t=2.15,P<0.05;t=142.63, P<0.01). Of the 45 cases undergoing reposition (29.6%),42 cases were still using the device. Conclusions:LNG-IUS is one of the effective treatments for dysfunctional uterine bleeding and adenomyosis of uterus. The reposition of the downward shifted LNG-IUS under the guidance of B ultrasound is safe and feasible.
Keywords:Intrauterine devicesIntrauterine device expulsionmedicatedFunctional uterine bleedingEndometriosisMenorrhagia
Publication Date:2013-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:3( 247-249 )