Application value of the small field HyperCUBE sequence and compressed sensing HyperSense technology in high-definition imaging of single hip joint
LIAN Yufei
HAN Xiaodong
HUANG Zhongxia
WU Tao
Abstract:Objective To explore the application value of small field HyperCUBE sequence and compressive sensing(HS)technology in high-definition imaging of single hip joint,in order to shorten scanning time and optimize scanning process while ensuring image quality.Methods Twenty healthy volunteers,half male and half female,aged 20-35 years old were employed.All volunteers underwent unilateral coronal hip joint scans on a 1.5T MRI.The scan sequences were as followed:conventional HyperCUBE,HyperCUBE with HS(HS factor 1.25,1.5,2.0,respectively),with scan times of 6 min 21 s,3 min 22 s,2 min 14 s,1 min 41 s,respectively.After the scanning was completed,subjective and objective evaluations were conducted on the 4 sets of images.The subjective evaluation was conducted by two associate chief physicians with more than 10 years of imaging diagnosis experience by using a"5-point method"for double-blind evaluation.The subjective evaluation items included image uniformity,artifacts,image blur degree,and overall image quality.The results were statistically analyzed using rank sum test,and the consistency of the evaluators will be analyzed using Kappa analysis;Objective evaluation was based on image signal-to-noise ratio(SNR),background noise,and contrast noise ratio(CNR),and results were analyzed via using univariate analysis of variance for statistical analysis.Results The subjective scores for conventional HyperCUBE,HyperCUBE with HS(HS factor 1.25),HyperCUBE with HS(HS factor 1.5),HyperCUBE with HS(HS factor 2.0)were as followed:the quartiles of image uniformity were(4,5),(4,5),(4,5),(4,5)(P>0.05);The quartiles of image artifact were(4,5),(4,5),(3,4),(3,3)(P<0.05);The quartiles of image blur degree were(4,5),(4,5),(3.25,4),(3,2)(P<0.05);The quartiles of overall image quality were(4,5),(4,5),(3.25,3),(2.25,2.50)(P<0.05).The objective scores of four groups were as followed:femoral head SNR:34.54±3.65,44.98±3.41,30.54±1.32,29.54±1.98(P<0.05);Background noise:10.69±1.13,5.54±1.31,3.54±1.28,2.11±1.98(P<0.05);Femoral head muscle CNR:163.45±11.47,168.61±15.12,161.61±15.12,168.45±10.67(P>0.05).Conclusion The HyperCUBE small field 3D ultra long echo chain pseudo steady state fast spin echo sequence can shorten the scanning time without increasing oversampling and scanning time by applying ultra selective saturation pulses.In addition,the combination of the new MRI acceleration technology HyperSense can further accelerate the scanning speed,providing strong support for clinical 3D high-definition single hip joint scanning.HyperCUBE with HS1.25 could exhibit the imaging capability of the best image quality.
Keywords:HyperSenseHyperCUBEMRIhip joint
Publication Date:2025-03-20
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:6( 347-352 )
Journal of Molecular Imaging

Journal of Molecular Imaging

ISTIC
ISSN:1674-4500
Year, Vol.(Issue):2025,48(3)