Comparative study on the image quality of partial solid nodules in the lungs based on energy spectrum CT virtual plain scan and conventional plain scan
HONG Jingjing
WEN Ge
ZHANG Fei
ZHANG Lianlian
LIU Disi
HUANG Weikang
Abstract:Objective To investigate the feasibility of utilizing virtual non-contrast enhanced(VNC)images derived from dual-energy computed tomography(DECT)for the assessment of part-solid nodules(PSN)within the lung,and compare the image quality with that of true non-enhanced(TNC)images.Methods A retrospective analysis was conducted on 46 patients with solitary pulmonary nodules at our institution from January 2022 to January 2023.Patients underwent both TNC scanning and contrast-enhanced DECT scanning during the arterial and venous phases,with dual-phase VNC images reconstructed from the dual-phase DECT data.CT values,noise(standard deviation),and lesion diameters of PSN and the ipsilateral erector spinae muscle were measured on both dual-phase VNC and TNC images.The signal-to-noise ratio and contrast-to-noise ratio for PSN were calculated.Effective radiation doses in TNC and VNC modes were recorded.Subjective scoring was performed by two experienced radiologists using a 5-point scale.Non-parametric tests were employed to compare the subjective and objective parameters,as well as the effective radiation doses,of images obtained at different scanning phases.Kappa tests were utilized to evaluate the inter-rater agreement of the subjective scores provided by the two radiologists.Results The objective evaluation metrics(diameter,CT value,standard deviation,signal-to-noise ratio,contrast-to-noise ratio)between arterial and venous phase VNC and TNC images were not statistically significant(P>0.05).The mean subjective score for TNC images was the highest,followed by venous phase VNC images,with arterial phase scores being the lowest.There was a statistically significant difference in the scores among the three groups(P<0.001),yet both phases of VNC met diagnostic requirements.The inter-rater agreement for the subjective scores between the two radiologists was strong,with a range of 0.63 to 0.73.The use of VNC in place of TNC resulted in an approximate 30%reduction in radiation dose.Conclusion The dual-phase spectral CT with virtual non-contrast venous phase imaging provides image quality comparable to conventional non-contrast imaging and significantly reduces patient radiation exposure,making it particularly suitable for patients requiring multiple follow-up examinations.
Keywords:part-solid nodulevirtual non-contrastspectral CTradiation doseimage quality
Publication Date:2024-05-28
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:5( 528-532 )
