Shaking table test on utility tunnel under longitudinal near-fault velocity pulse ground motion
Chu Jian
Chen Hongjuan
Li Xiaojun
Gao Mingzhen
He Qiumei
Zhou Longyun
Abstract:With the accelerated development of urban underground infrastructure,utility tun-nels have become a critical component of lifeline systems.Ensuring their seismic resilience is essential,particularly in near-fault zones where ground motions often exhibit distinct velocity pulse characteristics.These pulses,characterized by short durations and high amplitudes,can drastically alter the seismic response of buried structures.However,systematic experimental research on how these velocity pulses affect the seismic behavior of shallow-buried,high-stiffness utility tunnels is still scarce.This study addresses this gap by conducting a series of shaking table tests with longitudinal input motions to investigate the dynamic responses of a util-ity tunnel-soil system under velocity pulse-type and non-pulse-type ground motions. The experiments were carried out on a shaking table array consisting of nine sub-tables.A 1/30 scaled model of the utility tunnel,made of organic glass due to its favorable mechanical similarity to the prototype,was carefully embedded within model clay soil.Actual near-fault ground motion records with velocity pulses and synthetic non-pulse ground motions whose response spectra are matched to relevant standards were employed as inputs.The peak ground acceleration(PGA)was scaled to three levels:0.10g,0.20g,and 0.30g.Accelerometers and laser displacement sensors were installed at various depths and structural levels to capture dy-namic responses including acceleration,displacement,and frequency content. The main findings are summarized as follows:①Velocity pulse motions significantly amplified the seismic responses of the soil,particularly near the surface.These included great-er peak accelerations and displacements compared to non-pulse velocity inputs.As the input in-tensity increased,the predominant frequency of the soil decreased,indicating stiffness degrada-tion and energy redistribution caused by pulse effects.②The structural response of the utility tunnel was also strongly affected by pulse characteristics.Acceleration amplification factors in-creased markedly at the upper levels of the structure under pulse-type ground motions,reveal-ing enhanced vertical energy transmission.③The soil and structure exhibited synchronized dynamic behavior,particularly in terms of predominant frequency and spectral shape.How-ever,the upper structural levels,due to reduced confinement,displayed more pronounced re-sponses,indicating the emergence of free-vibration characteristics and reduced soil-structure constraint. This study systematically examines the amplification mechanism induced by near-fault ve-locity pulse ground motions on utility tunnels.It reveals the interplay between input motion characteristics,structural geometry,and soil-structure interaction under strong ground motion scenarios.The results provide valuable experimental evidence.
Keywords:near-faultvelocity pulseutility tunnelshaking table testseismic response
Publication Date:2025-05-30
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:17( 438-454 )
Acta Seismologica Sinica

Acta Seismologica Sinica

ISTICPKUCSCD
ISSN:0253-3782
Year, Vol.(Issue):2025,47(3)