Test methods for nonlinear parameters of seismic data recorders and their effect analyses
LiCaihua
TengYuntian
LiXiaojun
TangYixiang
WangZhe
HuXingxing
ZhangYang
Abstract:Total harmonic distortion (THD) and intermodulation distortion (IMD) characteris-tics are two important nonlinear parameters of seismic data recorders. Input signal mode and peak value of sine-wave can affect the test results of these two characteristics. In order to deter-mine these effects, the basic principles on THD and IMD were introduced in this paper, and then test methods, data processing methods and effect analyses on THD and IMD were fully presented. Finally, some different kinds of sine-waves were input into the seismic data recorder to test THD and IMD. The test results show that the two signals with the same peak value but different input-mode have great impact on THD, and those with the same frequency but different peak value of sine-wave have great impact on IMD. However, signal frequency variation has no impact on THD and IMD. The research in this paper is of great value for quality test of seismic data recorder, which can be applied to test THD and IMD of seismic data recorders.
Keywords:seismic data recorderquality inspectionnonlinearitytotal harmonic distortion (THD)intermodulation distortion (IMD)
Publication Date:2019-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:8( 92-99 )
Acta Seismologica Sinica

Acta Seismologica Sinica

PKUISTIC
ISSN:0253-3782
Year, Vol.(Issue):2019,41(1)