Pitch Optimizing Combination of Thoracic and Abdominal CTA Image Quality and Radiation Dose Discussion
Abstract:Objective:To evaluate the pitch of the thoracic and abdominal MSCT CTA image quality,and compare the radiation dose.Materials and Methods:Collection of clinical suspected thoracic and abdominal vascular lesions in 90 patients,according to the different pitch were randomly divided into 3 groups(n=30),group A:a pitch of 1.375:1,55 mm/s bed velocity;group B:a pitch of 0.984:1,39.37 mm/s bed velocity;group C:pitch,0. 516:1 bed velocity 20.62 mm/s,using the same injection rate and dose of contrast contrast tracking trigger scanning.After obtaining data from imaging director and supervisor technician in a AW4.4 workstation for image quality evaluation.Results:Through the pitch after optimization,A,B,C 3 groups average each patient scan time respectively:(12.60±0.54)s,(17.40±0.44)s,(33.10±1.48)s,DLP respectively:(1 462.50±71.56)mGy.cm, (2 010.55±62.14)mGy.cm,(3 821.58±198.50 the difference between mGy.cm),which was statistically significant(P0.05), recombinant vascular definition and display of vascular branching number also no difference.Conclusion:The groups A pitch optimization,fast bed velocity scanning parameters can significantly reduce the patient radiation dose,so as to ensure the image quality and meet the requirements of diagnosis.
Keywords:MSCTradiation doseimage qualitypitch factor
Publication Date:2012-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:7( 305-311 )