Analysis of the Reasons about the Low Hardness Values of the High-temperature Reheater of the Power Plant Boiler
Abstract:During the installation for the 300MW grade thermal power plant boiler, hardness values are low?? of high-temperature boiler reheater's tube socket situation. This article analyzes the reasons through the multiple analysis methods on hardness testing, chemical analysis, metallographic phase.
Keywords:power plant boilerhigh-temperature reheaterhardness valuesanalysis of the reasons
Publication Date:2011-01-01
Online Publishing Date:2025-08-15(First online date of this platform, not the publication date of the document)
Pages:2( 7-8 )